N309730U

U.L. CSA Recognized Wire

CSA Certified Business Machine Wire

CSA-Certified
Business Machine Wire
AWM I A/B (previously S-R PVC, T2)
Rated: 80ºC or 300 Volt
.009” Semi-Rigid Vinyl Insulation
Meets UL Style 1061 and MIL-W-16878/1, except where noted.
Wires certified by the Canadian Standards Association for radio or electronic use. Case File No. LL-32511.

Specifications

Agency Voltage Rating 300 Volts
Factory Spark-Test Voltage 5000 VAC. 100% of all wire is tested at this voltage.
Insulation Breakdown Voltage > 7000 volts, peak.
IR: Insulation Resistance, wet > 2000 megohm/100 mtr, metal to water bath at +20ºC
Nominal Dielectric Constant value 4
Flame Properties Self extinguishing. Meets UL VW-1
Fungus Fungus resistant

DOWNLOAD PDF CSA-Cert. BUSMACHINE WIRE. Also listed in the National Wire Printed Catalog.

RoHS products are listed with an "R" in the second position of the Part Number.

Color Information and Instructions for Ordering

Standard basic insulation color numbers are: Black: 0, Brown: 1, Red: 2, Orange: 3, Yellow: 4, Green: 5, Blue: 6, Violet: 7, Gray: 8, White: 9. The insulation color code number, may be 1, 2 or 3 digits depending on the number or absence of stripes. The 1st number is color of Insulation, 2nd number is color of first stripe; 3rd number is color of the second stripe. Example: White wire(9) + Red stripe(2) + Black stripe(0) makes a color code number of “9-2-0”. That color number, “9-2-0” is appended to the part number. Sample part number might be “xxxxxx-xxx-9-2-0”

Download Color Information

GAUGE OF CONDUCTOR22
GAUGE OF STRANDS30
MAX RESISTANCE DC AT 20° C PER 1000 FEET16.7
MAX RESISTANCE DE AT 20 ° C PER KM55
NOM. DIAM. STRANDED CONDUCTOR (INCHES)0.03
NOM. DIAM. STRANDED CONDUCTOR (MM)0.762
NOM. FINISHED WIRE DIAM. (INCHES)0.05
NOM. FINISHED WIRE DIAM. (MM)1.27
NOM. WEIGHT LBS. PER 1000 FEET3
NOM. WEIGHT KG/KM PER 1000 FEET4.46
NUMBER OF STRANDS7.00
 