NQ SERIES
Cabled Single Conductors
Mil Spec, U.L. AWM
Recognized Style 2464 and CSA Certified AWM II A/B
National Wire & Cable Corporation manufactures a complete line of highly flexible micro-miniature low-voltage instrument control cable .These are available as cabled pairs or singles, with optional overall shield of either foil with drain or a braided shield.
Conductors are stranded tinned copper with .010” wall of tough extruded polyvinyl chloride primary insulation, rated for 300 volt use at +80°C under U.L. style 1061*. All are color coded using ten standard colors plus white with stripes per MIL-STD-681.
Conductors are planetary cabled and helically laid for optimum flexibility, with a barrier under braids. Shielded cables have a tinned copper braid of 90% coverage per
MIL-C-7078, with braid angles below 40° for easy pushback; or have 100% coverage foil shield in intimate contact with a drain wire for easy termination.
The outer jacket is highly flexible abrasion-resistant gray polyvinyl chloride thermoplastic, meeting the requirements of U.L. style 2464. The jacket material is military rated for 105°C; meets MIL-l-631, Type F. Meets EIA for RS-232, 18-24 gauges.
Military certification furnished only when requested.
All materials are flame retardant and fungus resistant. Standard Putups: 500 and 1000 ft. No-deposit reels. For shorter quantities or specific lengths, consult factory.
*Wire also meets MIL-W-16878, rated 600 volts, +105°C.
Insulation Breakdown Voltage | Greater than 3400 volts AC RMS, 60cps. | |
Capacitance | Nominal capacitance from a wire to all else in a cable ranges from 25 to 45 pf/ft at 1 kc, depending on gauge and position. | |
Insulation Leakage | 200 megohms/1000 feet minimum @ 500 VDC form conductor to all else in cable. | |
Sheath Leakage | 10 megohms/1000 feet minimum @ 500 VDC from shield or conductor group through sheath to ground. | |
Bending Characteristics | All cables are suitable for flexing to a circle diameter of 6 cable diameters from +105°C to -20°C. Recommended flex diameter should be greater than 20 cable diameters for flexing at -40°C. For continuous flexing applications consult the factory. | |
Temperature Range | U.L. rating: +80°C per U.L. style 2464. - Military: Continuous use from -40°C to +105°C. | |
Foil Shielded Cables | The nominal over-all diameter of foil shielded cables will be .006” greater than the non-shielded cables of the same conductor count and wire size. | |
Characteristic Impedance (NQP Paired Cables) | Ranges from 150 ohms to 45 ohms, dependent on wire size (AWG), geometry and drive method. Consult our technical staff for data on specific cable types. | |
DOWNLOAD PDF for NQ Cable. Also listed in the National Wire Printed Catalog.
RoHS products are listed with an "R" in the second position of the Part Number.
JACKET COLOR | gray pvc |
UNSHIELDED | Yes |
GAUGE OF CONDUCTOR | 26 |
JACKET WALL (INCHES) | 0.032 |
JACKET WALL (MM) | 0.8 |
NOM. DIAM. STRANDED CONDUCTOR (INCHES) | 0.039 |
NOM. DIAM. STRANDED CONDUCTOR (MM) | 1 |
NOM. FINISHED WIRE DIAM. (INCHES) | 0.341 |
NOM. FINISHED WIRE DIAM. (MM) | 8.7 |
NOM. WEIGHT LBS. PER 1000 FEET | 71 |
NOM. WEIGHT KG/KM PER 1000 FEET | 105 |
NUMBER OF CONDUCTORS | 37 |