Military & UL Grade
Single Conductors (NTS Series)
RFI Shielded Cables
Meets U.L. Style 2343 or 2344 for Computer Use
National Wire & Cable Corp. manufactures a complete line of flexible signal and control cables in which each conductor is individually shielded and plastic-jacketed. Conforming to MIL-C-27072, these cables provide extended temperature, rough usage, military shielding, excellent flexibility. Provides a minimum of crosstalk between signal channels, plus complete isolation between shields. Excellent for analog signals. All jackets are moisture proof and suitable for use in duct, conduit, aerial, or burial installations.
Conductors are stranded tinned copper with .010” vinyl primary insulation plus .004” nylon insulation over the vinyl per MIL-DTL-16878/17. Insulation for 600 volts working rating at 105°C. Color-coding: White. All conductors are 19 strand.
Shielding is tinned copper braid with 85-90% coverage per MIL-C-7078, and shield angle below 40 degrees for easy pushback.
F. Each subcable is individually identified by color code per MIL-STD-681, starting with color #9.
All sub-components are planetary cabled and contra-helically laid with a mylar tape serve over the cable bundle. The overall sheath is abrasion- resistant black 105°C vinyl thermoplastic per MIL-I-631, Type F.
Optional overall shielding of cabled bundle is 85-90% minimum coverage of tinned copper braid applied per MIL-C-7078 over the tape serve under sheath.

 

 

Specifications

Insulation Breakdown Voltage Greater than 5000 volts AC RMS, 60 Hz.
Insulation Leakage Res. 200 Megohms/1000 ft. at 500 VDC from any conductor to all else in cable.
Sheath Leakage Res. 10 Megohms/1000 ft. min. at 500 VDC from overall shield through sheath to saline bath at 25°C.
Usable Temp. Range Suitable for continuous use from +105°C to -56°C when stationary. Flexing service: +105°C to -25°C.
Bending Characteristics All cables are suitable for flexing to a circle diameter of 6 cable diameters from +105°C to -20°C. Recommended flex diameter should be greater than 20 cable diameters for flexing at -40°C. For continuous flexing applications consult factory.
Crosstalk Common-mode, adjacent subcables: Worst case, -80 db @ 1 Mhz; totaling to -100 db below 100 Mhz. (Ref. MIL-C-23437 for test method.) For 100 ft. test length.
Capacitance (pf/d/ft.) 16 AWG, 132 Wire-Shield, 18 AWG, 117 Wire-Shield, 20 AWG, 97 Wire-Shield, 22 AWG, 83 Wire-Shield, 24 AWG, 72 Wire-Shield, 26 AWG, 62 Wire-Shield
  PART NUMBERJACKET COLORDELAYS NS FTFINISHED CABLE DIAM. (INCHES)FINISHED CABLE DIAM. (MM)OVERALL FOIL SHIELD WITH DRAINOVERALL BRAIDED SHIELDOVERALL SHIELDEDUNSHIELDEDSHEATH TYPETC BRAID SHIELDGAUGE (AWG)GAUGE OF CONDUCTORGAUGE OF STRANDSINSULATION O.D. (INCHES)JACKET WALL (INCHES)JACKET WALL (MM)MAX RESISTANCE DC AT 20° C PER 1000 FEETMAX RESISTANCE DE AT 20 ° C PER KMNEMA SPEC HP3WIRE PART NUMBERNOM. CABLE DIAM. (INCHES)NOM. CABLE DIAM. (MM)NOM. CABLE O.D. (INCHES)NOM. CABLE O.D. (MM)NOM. CAPACITANCE PER FT WIRE SHIELDNOM. CAPACITANCE PER FT WIRE WIRENOM. DIAM. STRANDED CONDUCTOR (INCHES)NOM. DIAM. STRANDED CONDUCTOR (MM)NOM. FINISHED WIRE DIAM. (INCHES)NOM. FINISHED WIRE DIAM. (MM)NOM. WEIGHT LBS. PER 1000 FEETNOM. WEIGHT KG/KM PER 1000 FEETNON MILITARYNOT CSA CERTIFIEDNOT UL RECOGNIZEDNUMBER OF CONDUCTORSNUMBER OF PAIRSNUMBER OF QUADSNUMBER OF STRANDSNUMBER OF TRIADSOVERALL CONDUCTOR DIAM. (INCHES)OVERALL CONDUCTOR DIAM. (MM)OVERALL DIAM. (INCHES)OVERALL DIAM. (MM)ROHSMILSPEC ONLYFOIL SHIELDMIL SPEC PART NUMBERNON UL1007UL1569 ONLYCIRCULAR MIL AREA10 KVDC .036 WALL (INCHES)10 KVDC .036 WALL (MM)20 KVDC .045 WALL (INCHES)20 KVDC .045 WALL (MM)30 KVDC .055 WALL (INCHES)30 KVDC .055 WALL (MM)40 KVDC .090 WALL (INCHES)40 KVDC .090 WALL (MM)META TITLEMETA DESCRIPTIONMETA KEYWORDS
 

Enter quantity in feet
NRTS726J       1   26  0.062      0.41310.50      94139   7    0.095   1